All penetrations must be air sealed as well.
Furnace closet door requirements.
Once your combustion vents have been installed and the ceiling in the closet has been finished out you will want to close off any vents in the door.
You can do this by attaching a piece of plywood on the back side of the door.
Keep checking the draft also for good measure open and close the garage door and an outside door on another side of the house note you want the draft to be between 0 01 and 0 02 water column inches.
Less isn t good especially in winter when drafts tend to run higher.
The key is that you have to install air inlets so that the furnace or water heater gets the combustion air it needs when it s running.
Be sure to caulk around the seams to make a tight seal.
More well judgment call but be sure the draft isn t so strong it is creating an air curtain across the discharge into the draft hood more likely on the water heater in my experience.
Unscrew the hinges from the furnace room door with a screwdriver.
Provide a door with a vented front large enough to provide the necessary air supply.
Place the door across two sawhorses.
Replace the door by reattaching the hinges.
Refer to the furnace installation.
A furnace malfunction can cause a deadly carbon monoxide co buildup.
So the florida building code fbc g2406 and international residential code irc do not allow furnace installation in a bedroom bathroom or an any adjoining closet unless it meets these specifications that essentially isolate the furnace from the room.
Close off vents in door.
The closet shall be for the exclusive use of the water heater.
Cut off the bottom few inches of the door with a circular saw to create a gap that allows air to vent into the furnace room.
Enclose any furnace cabinet with gypsum drywall which is fire resistant.
When locating the walls be sure to allow enough space at least 30 inches to move around inside the furnace room so that maintenance and repairs can be performed on the furnace.
The door must have weatherstripping and a threshold to prevent air leakage between the closet and the house.
The door assembly shall be installed with a threshold and bottom door seal and shall meet the requirements of section 504 1 2.
Door assembly shall meet the requirements of section 504 1 1.